Please use this identifier to cite or link to this item: https://idr.l1.nitk.ac.in/jspui/handle/123456789/10242
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPragadeesh, K.S.
dc.contributor.authorSudhakar, D.R.
dc.date.accessioned2020-03-31T08:18:47Z-
dc.date.available2020-03-31T08:18:47Z-
dc.date.issued2019
dc.identifier.citationEnergy and Fuels, 2019, Vol.33, 5, pp.4542-4551en_US
dc.identifier.urihttp://idr.nitk.ac.in/jspui/handle/123456789/10242-
dc.description.abstractChemical looping combustion (CLC) is one of the promising fuel conversion technologies for carbon capture with low energy penalty. Devolatilization is an important physical phenomenon occurring during solid fuel CLC. Devolatilization behavior influences fragmentation, combustion rate, emission, and particulates generation in fluidized bed CLC (FB-CLC), thus a critical input for its design. Existing visual techniques for determining devolatilization time cannot be applied in CLC conditions because of its flameless combustion nature. In the present study, a new, simple, and quick technique called "color indistinction method" (CIM) is proposed for the determination of devolatilization time (?d) in FB-CLC, where the end of devolatilization is inferred from the disappearance of fuel particle in a hot fluidized bed. Single-particle devolatilization studies in FB-CLC are conducted to determine the devolatilization time using CIM for two types of fuels, viz., coal and biomass (Casuarina equisetifolia wood), of size range 8-25 and 10-20 mm, respectively, at three different fuel reactor bed temperatures (800, 875, and 950 C) and one fluidization velocity. The proposed technique is validated in three ways: (i) the measurement of residual volatiles present in char by thermogravimetric analysis; (ii) mass loss history of the fuel during devolatilization; and (iii) diagnostics using particle center temperature measurements. The results of CIM experiments, in terms of degree of error involved, are compared with an established flame extinction technique (FET) and a more accurate particle center temperature (PCT) method. The amount of volatiles released during devolatilization, as determined by CIM, is 91.3% for coal and 98.9% for biomass. These values compare very well with the results of the established FET, in which the volatile release is 90.7% for coal and 99.1% for biomass samples. The devolatilization times determined using CIM are in line with particle center temperature measurements with an acceptable error range of -7.57 to +3.70%. The proposed CIM is successful in establishing the devolatilization time of different fuels in CLC conditions and can also be applied in other flameless combustion conditions. 2019 American Chemical Society.en_US
dc.titleColor Indistinction Method for the Determination of Devolatilization Time of Large Fuel Particles in Chemical Looping Combustionen_US
dc.typeArticleen_US
Appears in Collections:1. Journal Articles

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.