Please use this identifier to cite or link to this item:
https://idr.l1.nitk.ac.in/jspui/handle/123456789/15256
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Thimmaiah S. | |
dc.contributor.author | Wahidi T. | |
dc.contributor.author | Yadav A.K. | |
dc.contributor.author | Mahalingam A. | |
dc.date.accessioned | 2021-05-05T10:26:49Z | - |
dc.date.available | 2021-05-05T10:26:49Z | - |
dc.date.issued | 2020 | |
dc.identifier.citation | Journal of Thermal Analysis and Calorimetry , Vol. 141 , 6 , p. 2219 - 2229 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s10973-020-09854-x | |
dc.identifier.uri | http://idr.nitk.ac.in/jspui/handle/123456789/15256 | - |
dc.description.abstract | Natural circulation loop (NCL) is a geometrically simple heat transfer device in which fluid flow occurs due to density gradient of loop fluid, induced by the temperature difference between the source and the sink. NCL has an inherent problem of instability caused by the combined effect of buoyancy, friction and inertia forces at varying operating conditions, and hence it requires an elegant solution of instability. The primary objective of the present work is to do a comparative study on the dynamic performance between two different configurations of NCL based on supercritical CO2, i.e. (i) NCL with isothermal heater and a cold heat-exchanger (ISO-CHX), and (ii) NCL with hot and cold heat-exchangers (HHX-CHX). To explore these NCLs, two-dimensional transient computational fluid dynamics studies have been carried out on the stability of supercritical CO2-based natural circulation loop. Results are obtained for different operating pressures and temperatures in the form of mass flow rate and velocity variation with respect to time. Results show the higher instabilities in both side heat-exchanger loop than an isothermal heater with heat-exchanger loop. At a lower rate of heat input at source in the HHX-CHX loop, the mass flow is bidirectional, whereas it is unidirectional in the ISO-CHX loop at all level of heat input. It is also observed that as pressure increases, flow instability also increases. Obtained results are validated with the published experimental and numerical data and found in good agreement. © 2020, Akadémiai Kiadó, Budapest, Hungary. | en_US |
dc.title | Comparative computational appraisal of supercritical CO2-based natural circulation loop: effect of heat-exchanger and isothermal wall | en_US |
dc.type | Article | en_US |
Appears in Collections: | 1. Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.