Title: Failure of a Cooling Water Pump Shaft
Authors: Sondar P.R.
Kumar J.K.R.
Chawla S.
Dsilva P.C.
Hegde S.R.
Issue Date: 2020
Citation: Journal of Failure Analysis and Prevention Vol. , , p. -
Abstract: This study investigates the failure of an industrial cooling water pump which experienced a drive shaft failure. As per the fail-safe design, during adverse loading of the shaft, key should fail by shear. The key, if fails, can be easily replaced to resume the operation of the pump. However, this investigation reveals that both the key and the shaft failed due to materials processing issues. A detailed failure analysis was carried out including design calculations, visual inspection, dye penetrant inspection, magnetic particle inspection, hardness test, microstructural analysis, and fractography. The study found that the hardness of the shaft varied radially from the core to the surface. The subsurface of the shaft near the keyway, happened to be significantly softer than the key. During operation, the keyway widened by plastic deformation and caused rattling of the key. Due to rattling and vibration, the key developed numerous fatigue cracks and eventually failed by crack linkages. The shaft eventually failed by torsional shear near the midpoint of the keyway. The analysis adjudged hardness variation in the shaft due to materials processing issues as the root cause of the failure. © 2020, ASM International.
URI: https://doi.org/10.1007/s11668-020-01043-0
http://idr.nitk.ac.in/jspui/handle/123456789/16262
Appears in Collections:1. Journal Articles

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.